40
Amp, 12, 24, and 48v adjustable, 3-stage charge controller
60 Amp, 12 and 24 adjustable, 3-stage charge controller
For current pricing, call us toll-free 1-877-964-4188.
A Controller for Virtually any DC Charging Source. The C40 and C60 are fully solid state, microprocessor-driven controllers that can be used for battery charging, DC load control or DC diversion operation,
and come with a standard multi-color charge status LED.
Standard Features:
Silent Microprocessor Control
All C Series controllers have a powerful microprocessor at their core which increases system performance and maximizes battery life. They are fully solid state and operate silently.
PWM Charge Performance
C Series controllers all use Pulse Width Modulation (PWM) charging profiles which are designed to provide a full charge to your battery while, at the same time, minimize gassing which can shorten battery life.
3-Stage Battery Charging
All C Series controllers automatically initiate a 3-stage battery charging cycle. Bulk, Absorption, and Float modes are used to ensure that voltage and current settings accurately match the batteries' actual state of charge. This means fast-as-possible charging and extended battery life. An auto equalize mode can be easily switched off when the controller is used with sealed batteries. C Series controllers are factory set for solar PV battery charging operation.
Field Adjustable
There are a number of field configurable, user adjustments for C Series controllers. The C40 may be configured for 12, 24 or 48 volt systems. Bulk and Float voltage set points are user adjustable which allows use with a wide variety of battery technologies including; flooded lead acid, gel, and absorbed glass mat. In addition, there are manually selectable settings for Nicad batteries.
DC Load Controller Mode
When used as a load controller, the C Series will automatically turn a DC load on or off at predetermined battery voltage settings. Both LVD (low voltage disconnect) and LVR (low voltage reconnect) set points are user adjustable.
DC Diversion Mode
In this mode, all power, which is not used to maintain a full charge on the batteries, is diverted to a load dump such as water or space heaters. Diversion mode is used to regulate microhydro and wind turbine systems which need a constant load.
LED Status Indicator
A simple to read, multi-color LED indicates operating status and is standard on all C Series controllers.
UL and cUL Listed
C Series controllers are listed by UL to exacting UL 1741 and cUL CSA 22.2 107.1-95 standards. C Series controllers are also CE compliant (European countries) and are designed to CTIK standards (Australia). Their current ratings are "real world" and do not have to be derated to comply with USA NEC 125% overcurrent requirements.
| Electrical Specifications |
C40 |
C60 |
Voltage Configurations: |
12, 24 and 48 VDC |
12 and 24 VDC |
| Max. PV Open Circuit Array Voltage: |
125 VDC |
55 VDC |
| Charging / Load Current (at 25°C): |
40 amps DC |
60 amps DC |
| Max. Peak current: |
85 amps |
85 amps |
| Max. Voltage Drop through Controller: |
0.30 volts |
0.30 volts |
| Typical Operating Consumption: |
15 ma |
15 ma |
| Typical Idle Consumption: |
3 ma |
3 ma |
| Recommended Breaker Size: |
50 amps |
60 amps rated 100% continuous duty |
| Recommended Wire Size: |
#8 AWG |
#6 AWG rated at 90 degrees C |
| Lead Acid Battery Settings: |
Adjustable |
Adjustable |
| NiCad Battery Settings: |
Adjustable |
Adjustable |
| |
|
|
| General Specifications |
|
|
| Specified Temperature Range: |
32° F to 104° F (0° C to 40° C) |
32-104 degree F (0-40 degree C) |
| Enclosure Type: |
Indoor, ventilated, powder coated steel with 3/4" and 1" knockouts |
Indoor, ventilated, powder-coated steel with 3/4" and 1" knockouts |
| Unit Weight: |
3.0 lb (1.4 kg) |
3.0 lbs (1.4 kg) |
| Shipping Weight: |
3.5 lb (1.6 kg) |
3.5 lb (1.6 kg) |
| Dimensions (H x W x D): |
10 x 5 x 2.5" (25.4 x 12.7 x 6.35 cm) |
10"x5"x2.5" (25.4 x 12.7 x 6.35cm) |
| Shipping Dimensions (H x W x D): |
12.4 x 7 x 2.5" (31.5 x 17.8 x 6.4 cm) |
12.4 x 7 x 2.5" (31.5 x 17.8 x 6.4 cm) |
| Mounting: |
Vertical wall mount - indoor only |
Vertical wall mount - indoor only |
| Altitude - Operating: |
15,000' (4,572 m) |
15,000' (4,572 m) |
| Altitude - Non-Operating: |
50,000' (15,240 m) |
50,000' (15,240 m) |
| Warranty: |
Two years |
Two years |
Load Control Mode: Low Voltage Reconnect - Adjustable (sticker provided with unit) all models Low Voltage Disconnect - User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a one time, user selectable grace period) all models
Options
Display Panel: CM, CM/R-50, or CM/R-100 - optional LCD - backlit, alphanumeric display showing battery voltage, DC amperage, cumulative amp hours, and amp hours since last reset - remote includes 50' (15 m) or 100' (30.5 m) cable
Battery Temperature Sensor: BTS - optional remote battery temperature sensor for increased charging precision
|